Myocardial perfusion imaging using technetium 99m-tetrofosmin : (Record no. 4731)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01966nam a22002057a 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | DOH |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20210519110638.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 210519b ||||| |||| 00| 0 eng d |
| 245 00 - TITLE STATEMENT | |
| Title | Myocardial perfusion imaging using technetium 99m-tetrofosmin : |
| Remainder of title | A comparative study with coronary angiography / |
| Statement of responsibility, etc. | Josefina M. Lagunzad [and two others] |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | Results of resting and exercise tetrofosmin myocardial perfusion imaging of 54 patients (48 men and 6 women; mean age of 59) were reviewed and analyzed and compared with their respective coronary angiographic findings. Forty one patients with coronary artery disease (CAD) (50% luminal stenosis) had an abnormal myocardial scintigram. Four patients with significant CAD showed normal myocardial imaging. In one patient, the result of myocardial perfusion was equivocal. Six patients without significant CAD had normal perfusion imaging. Overall sensitivity, specificity and accuracy of tetrofosmin myocardial perfusion in the detection of significant CAD were 91%, 75% and 88% respectively. Positive predictive value was 95% while the negative predictive value was 60%. The localization of defects by tetrofosmin myocardial perfusion imaging in relation to the perfusion territories of stenosed vessels of 50% was achieved with 92% sensitivity, 50% specificity and 62% accuracy for the LAD, 87%, 59%, and 67% respectively for the Left Circumflex Artery and 89%, 58%, and 69% respectively for the RCA. Positive predictive values were 92%, 87%, and 89% for LAD, LCx, and RCA respectively, while negative predictive values were 30%, 59%, and 58%, respectively for LAD, LCx and RCA. |
| 580 ## - LINKING ENTRY COMPLEXITY NOTE | |
| Linking entry complexity note | <br/><br/>Makati Medical Center Proceedings, 1999 (13) pages 35-38 |
| 650 #2 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Exercise Test |
| 650 #2 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Coronary Disease |
| General subdivision | physiopathology |
| 650 #2 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Thallium Radioisotopes |
| 700 1# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Lagunzad, Josefina M. |
| 700 1# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Tan-Gatue, Robert D. |
| 700 1# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Lapitan, Raul L. |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Koha item type | Journal Article |
| 999 ## - | |
| -- | 4731 |
| -- | 4731 |
| Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Total Checkouts | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| National Library of Medicine | DOH Central Library | DOH Central Library | Electronic Resource Section | 05/19/2021 | J000654 | D0001J000654 | 05/19/2021 | 05/19/2021 | Journal Article |