<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01895nam a22002057a 4500</leader>
  <controlfield tag="003">DOH</controlfield>
  <controlfield tag="005">20210325104743.0</controlfield>
  <controlfield tag="008">210324b           ||||| |||| 00| 0 eng d</controlfield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Plastics :  </subfield>
    <subfield code="b">volatile substances in polystyrene /</subfield>
    <subfield code="c">Marilou U. Martinez [and two others]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">A total of 51 polystyrene samples, consisting of 32 in pellet forms and 19 as finished articles, were analyzed for the following volatile substances: toloune, ethyl benzene, isopropyl benzene, n-propyl benzene and styrene. These volatile substances were determined by gas chromatography. The volatile substances in 32 polystyrene pellet samples were found to be as follows: the toluene content ranged from not detected in 30 samples to 76 ppm; ethyl benzene content fron not detected in 3 samples to 878 ppm; isopropyl benzene content from not detected in 10 samples to 650 ppm; n-propylbenzene content from not detected in 12 samples to 453 ppm; styrene monomer content from 787 to 3059 ppm; total volatile substances from 787 to 3389 ppm. In 19 finished articles, the values obtained for toulene content ranged from not detected in 17 samples to 86 ppm; ethyl benzene content from not detected in 6 samples to 1797 ppm; isopropyl benzene content from not detected in 11 samples to 363 ppm; n-propyl benzene content from not detected in 11 samples to 178 ppm; styrene monomer content from 670 to 2705 ppm; total volatile substances from 677 to 4528 ppm. All samples were shown to contain styrene monometer, however, only 1 finished article and 5 pellet samples exceeded 2000 ppm level.(Author)</subfield>
  </datafield>
  <datafield tag="580" ind1=" " ind2=" ">
    <subfield code="a">BFAD  Laboratory Information Bulletin, 1995  1 (1) pages 35-41</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="2">
    <subfield code="a">Polystyrenes</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="2">
    <subfield code="a">Plastics</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="2">
    <subfield code="a">Volatilization</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2=" ">
    <subfield code="a">Volatile Substances</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Martinez,  Marilou U. </subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Balde, Helen A.  </subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Martin, Rosario E. </subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">JA</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">3768</subfield>
    <subfield code="d">3768</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">nlm</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">DOHCL</subfield>
    <subfield code="b">DOHCL</subfield>
    <subfield code="c">ElectronicRes</subfield>
    <subfield code="d">2021-03-24</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">J000317</subfield>
    <subfield code="p">D0001J000317</subfield>
    <subfield code="r">2021-03-24 00:00:00</subfield>
    <subfield code="w">2021-03-24</subfield>
    <subfield code="y">JA</subfield>
  </datafield>
</record>
