<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01782nam a22002057a 4500</leader>
  <controlfield tag="001">D0001J000334</controlfield>
  <controlfield tag="003">DOH</controlfield>
  <controlfield tag="005">20210325164301.0</controlfield>
  <controlfield tag="008">210325b           ||||| |||| 00| 0 eng d</controlfield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Determination of rifampicin in human plasma by reversed-phase liquid chromatography /</subfield>
    <subfield code="c">Maria Lourdes C. Santiago [and three others]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">A simple, specific and sensitive high pressure liquid chromatographic method for the determination of rifampicin in human plasma of Filipino male and female healthy volunteers was developed and validated
This method utilizes a direct precipitation separation technique and ultraviolet detection monitored at 337 nm. Dipyridamole is used as the internal standard. Rifampicin and the internal standard were separated using a Bakerbond narrow pore octyl (C8, 5um, 120 A, 4.6 x 250 nm) reversed-phase column with 10 mM phosphate buffer (pH 5.2), acetonitrile, and tetrahydrofuran (65:35:10) as the mobile phase. The retention time was 7.7 minutes for rifampicin and 14.5 minutes for dipyridamole. Results showed a linear response in the concentraion range of 0.5 to 20 mg/L (r=0.99925). The limit of quantitation is 0.5 mg/L. Both intraday and interday accuracy and precision data showed good reproducibility.
The precision, accuracy, linearity, specificity, and sensitivity of the method were well-within the range of clinical utility and meet the requirements for bioavailability, bioequivalence, and pharmacokinetic studies.(Author)</subfield>
  </datafield>
  <datafield tag="580" ind1=" " ind2=" ">
    <subfield code="a">BFAD  Laboratory Information Bulletin, 1997  3 (1) pages 30-35</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="2">
    <subfield code="a">Rifampin</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="2">
    <subfield code="a">Plasma</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Santiago, Maria Lourdes C. </subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Gonzales, Therese Irynne R. </subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Sarau, Josephine K. </subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Abejo, Vivianne O. </subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">JA</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">3785</subfield>
    <subfield code="d">3785</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">nlm</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="a">DOHCL</subfield>
    <subfield code="b">DOHCL</subfield>
    <subfield code="c">ElectronicRes</subfield>
    <subfield code="d">2021-03-25</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">J000334</subfield>
    <subfield code="p">D0001J000334</subfield>
    <subfield code="r">2021-03-25 00:00:00</subfield>
    <subfield code="w">2021-03-25</subfield>
    <subfield code="y">JA</subfield>
  </datafield>
</record>
