_aComparison of the hybrid locking plate, standard dynamic compression plate, and standard dynamic compression plate augmented with bone cement for fixation of osteoporotic humeral shaft fractures : _ba cadaveric biomechanical study / _cIrewin A. Tabu [and two others] |
| 520 | 3 | _aBACKGROUND: Studies comparing the relative strength of polymethylmethacrylate (PMMA) augmented fixation, standard plating and locked compression plate (LCP) system are few. The use of either the bone cement-augmented dynamic compression plate or the Hybrid LCP constructs may provide an additional tool for the treatment of fractures in patients with osteoporosis. METHODS: Eighteen (18) osteoporotic cadaveric humeral bones were assigned randomly to each of three groups (Dynamic Compression Plate [DCP], DCP augmented with bone cement, and the Hybrid LCP system) and tested in anterior-posterior bending and torsion/external rotation. The load to failure values were obtained and the results for each specimen compared. RESULTS: Significant differences were observed between the standard DCP and Hybrid LCP group (p-value=0.012), and in the cement-augmented and Hybrid LCP group (p-value=0.099) in torsion/external rotation loading. No significant difference was observed between the standard DCP and bone-cement augmented group (p-value=0.248). No significant difference was observed among the three groups in terms of stiffness (p-value=0.3868) in the four-point anterior-posterior bending modality. Screw pull-out of the implant was observed only in the regular DCP group in torsion/external rotation loading stress. CONCLUSION: Significant differences were seen between the three constructs in torsion/external rotation but not in anterior-posterior four-point bending. Bone failure, but not screw pull-out, was seen in the Hybrid LCP and bone cement-augmented DCP groups in torsion. This study showed that the LCP system and the bone cement-augmented constructs may provide greater screw purchase to the osteoporotic humerus. | |
| 580 | _aIn: Acta Medica Philippina, 2012 vol 46 (2) pages: 24-31 | ||
| 650 | 2 | _aHumeral Fractures | |
| 650 | 2 | _aOsteoporosis | |
| 650 | 2 | _aPolymethyl Methacrylate | |
| 650 | 2 | _aFractures, Compression | |
| 700 | 1 | _aTabu, Irewin A. | |
| 700 | 1 |
_aArbatin, Jose Joefrey F. _cJr. |
|
| 700 | 1 | _aBundoc, Rafael C. | |
| 856 | _uhttps://actamedicaphilippina.upm.edu.ph/index.php/acta/article/view/2155/1570 | ||
| 942 | _cJA | ||
| 999 |
_c2986 _d2986 |
||